Skip to content

Inlet lock

These configuration entries are all under the [vehicle] section.

Note

See also section Features/Lock safety.

locking_pulse_ms

Example
locking_pulse_ms = 600

To avoid burning the lock motor, it is driven only for a certain amount of time in one or the other direction. The length of these driving pulses default to 600 ms as it seems to correspond to most locking system available on the market. It can be configured to a different value if your lock is more peculiar.

Default to 600 ms.

Note

Internally, that value is capped to 2 seconds.

Note

To avoid damaging lock motors even in the most severe unexpected situations, we used special "watchdog" and "crash handler" to ensure the lock is de-energised even in case of a hard crash during a locking or unlocking sequence. Also note that de-energising means it will not complete the movement, nor unlock it. In such event, the lock will stay where it is, until the controller is restarted and user safety can be ensured.

lock_feedback_r_threshold

Example
lock_feedback_r_threshold = 100

Threshold, in ohms, between locked and unlocked state.

Default to 100 ohms.

lock_feedback_low_is_locked

Example
lock_feedback_low_is_locked = true

Polarity for lock_feedback_r_threshold when lock is locked. For instance, true means that the lock is locked when resistance is below the threshold. Whereas false means lock is locked when the resistance is above the threshold.

Default to true.

no_inlet_lock

Example
no_inlet_lock = true

If no inlet lock is used. Typical of table test use case, where you don't want to be blocking a simulated charge test because it cannot detects any lock.

Default to false.

Inlet lock examples

There are various lock feedback mechanisms existing. Here are examples for two most commonly found types of inlet locks.

Normally Open switch

With an NO switch, the lock feedback line will be shorted to ground (ie. R ~= 0 Ohms) when locked. In such case, the proper configuration is the following (which happens to correspond to default values):

lock_feedback_r_threshold = 100
lock_feedback_low_is_locked = true

1k / 11k resistance

With a 1k / 11k lock feedback, when the lock is open (or faulty) a 1 000 Ohms resistance is in the path to ground. When it is properly locked, that resistance becomes 11 000 Ohms. In such case, the proper configuration is the following:

lock_feedback_r_threshold = 5000
lock_feedback_low_is_locked = false