SAE J1939

By default the controller talks to your vehicle over the ADVANTICS generic CAN interface. If your BMS speaks SAE J1939 instead, the controller can bridge onto it: set enable_j1939_bridge and the same information is carried in J1939 PGNs.

The controller does not claim its address

device_address is static and the address claim protocol is not implemented. You must make sure the address you configure is not already taken by another device on that bus.

Entries marked advanced are hidden in the Web UI until you switch to expert mode.

[j1939]

  • default_priority: Priority applied to J1939 messages. Only when enable_j1939_bridge = true (default: 0)
  • device_address: J1939 source device address that should be used by the controller. Note that this address is static and that the controller does currently not implement the address claim protocol. Thus you need to make sure that the address configured here does not clash with other J1939 devices on the same bus. One of 0 to 253. Only when enable_j1939_bridge = true (default: 0)
  • enable_j1939_bridge: Uses J1939 for the communications with the backend (default: false)
  • j1939_can_if: CAN interface to which J1939 messages should be sent. Only when enable_j1939_bridge = true (default: can0)
  • peer_address: The device address used by your side. Default (0xFF) is to accept messages from any device address, but in case of PGN conflicts you may want to filter in the messages from a given source address. One of 0 to 255. Only when enable_j1939_bridge = true (default: 255)
  • vendor_pgn_offset: Can be used to solve ID conflicts in the J1939 vendoring space. All ADVANTICS vendor PGNs will be shifted by this offset. One of 0 to 192. Only when enable_j1939_bridge = true (default: 0) advanced