No BMS mode¶
Attention
No BMS mode should NEVER be used in normal conditions.
This is a special mode intended ONLY for testing or prototyping purposes. It allows you to not have to use a BMS (or not have to develop a bridge between our generic interface and the BMS protocol). The intended goal of this mode is to help you evaluate our controller and reach a demonstrative working charge in a short time span.
Normally, a BMS provide safe current request values with respect to the present state of charge of the battery. No BMS mode works by charging at a specific and static current, and automatically stops once a certain voltage is reached.
Warning
It is paramount that you pick sane and safe voltage and current settings for this! Charging a battery at too high current and/or above a certain voltage level can result in a catastrophic event.
The voltage to not charge over is to be configured with entry max_charge_voltage. When reaching
this voltage, charge will be cut-off immediately. This is different from entry max_voltage as
that one is for specifying the true maximum voltage of the battery when full (some commercial cars
even use values higher than the actual one). Though, both can have the same value, provided it is a
pretty low and safe one.
The amount of current used will correspond to entry max_current. Use a reasonably low value.
Tip
Use a partially discharged battery (one with a present voltage well below
max_charge_voltage). This is safer, and will make the demonstrative charge last longer.
Example: For a classic 403 V EV battery pack, a safe maximum charge voltage when not using a BMS would be 380 V. The current can be something like 20 A.
no_bms = true
max_charge_voltage = 380
max_current = 20
# Other typical settings (these won't affect the safe charge cut-off voltage)
max_voltage = 450
target_voltage = 410
no_bms¶
no_bms = true
Enables No BMS mode, in which the controller charges at a fixed current and cuts off on a voltage threshold rather than following a BMS request.
Default to false.
max_charge_voltage¶
max_charge_voltage = 380
The voltage at which the charge is cut off immediately.
Optional (ie. default to 0) when no_bms is false. It becomes required -- a non-zero value -- if
no_bms is true. Advantics controller also checks that max_charge_voltage is not configured to a
value greater than max_voltage.