| release 2.9.0 |
2026-09-04 |
- pev-controller 2.8.1
- Temperature monitoring: the cable temperature function is now the default, with derating, stop and monitoring enabled by default
- Inlet lock timing: a custom lock timing can now be configured by setting
enable_custom_lock_timing to True and the delay after the charger is detected via inlet_lock_delay_s (default 5 s, range 3–60). Whatever the value, the plug is always locked at the latest just before the insulation test - ISO15118-20 energy requests handling: when the BMS does not provide a value, the configured energy values are used as a fallback instead of sending zeros, and the maximum request is capped by the configured battery energy capacity
- Current deviation detection now also runs in dynamic mode against the current range
- Generic CAN interface V1 & V2: CAN IDs can now be remapped from the configuration file
- Plugged-in signalling: a single wake pulse is emitted when the new
plugged_in_pulse_ms hardware config entry is set on a digital output - Diagnostic messages are no longer sent while the controller is in the Emergency state until it settles
- Waking from sleep no longer reports a spurious node disconnection: required nodes are given a short grace period to reconnect before a
NODE DISCONNECTED error is raised, instead of reacting to the stale pre-sleep heartbeat
- ccs-evcc 2.8.2
- ISO15118-20 fix MessageHeader timestamps: the charger clock offset is now anchored once on SessionSetupRes, instead of being recomputed from every response
- ISO 15118-2: the optional
ChargingProfileEntryMaxNumberOfPhasesInUse element is no longer sent in PowerDelivery - Fix a 0 Wh energy request being treated as "not provided", which broke the required min ≤ target ≤ max ordering
- Use both Target Voltage and Target Current in Scheduled Mode by default
- Control Pilot state reporting: state A is now reported as soon as the pistol is unplugged
- Waking from sleep no longer reports a spurious node disconnection (see above)
- Fixed an issue with certificate management that could prevent the vehicle from transmitting a certificate
- slac-pev 2.4.0rc2
- Fix: prevent double CM_ATTEN_CHAR.IND when MNBC timeout and last sound arrive concurrently
- Waking from sleep no longer reports a spurious node disconnection (see above)
- Unknown SLAC message types are logged at debug level instead of info, cutting down the log noise
- advantics-csm 1.8.0
- Configuration file: every entry now carries a description and belongs to a category, so the generated
.cfg file and the web interface document themselves - Include the new config entries
|
Download link: evcc-release-2.9.0.zip |
| release 2.8.0 |
2026-06-26 |
- pev-controller 2.7.0
- ISO15118-20: cap energy requests based on config params
- Always report the state of the digital inputs over CAN bus regardless of their configuration
- Add possibility to use different CAN bus interfaces for IVT and Generic CAN interface using
can_sensor_if config entry - Retry IVT sensor configuration until it powers up after init/sleep. Capped by configured timeout
ivt_init_timeout_s - Add possibility to assert HV hold-off until the BMS reports ready using config entry
hold_off_until_bms_ready - Enable current derate function based on temperature
- pev-slac 2.4.0
- fix: In multi-EVSE, duplicate CM_SLAC_MATCH.CNF lingers in buffer causing cm_set_key to hard-fail
- advantics-csm 1.7.6
- TLS certificates management
- New configuration entries added
|
Download link: evcc-release-2.8.0.zip |
| release 2.7.3 |
2026-06-05 |
- advantics-csm 1.7.4
- Fix docker client issue that was leading to blocking behavior on image discovery
|
Download link: evcc-release-2.7.3.zip |
| release 2.7.2.post1 |
2026-06-01 |
- Fix system services update
|
Download link: evcc-release-2.7.2.post1.zip |
| release 2.7.2 |
2026-04-30 |
- advantics-csm 1.7.3
- Fix configuration issue with J1939 interface
|
Download link: evcc-release-2.7.2.zip |
| release 2.7.1 |
2026-04-23 |
- pev-controller 2.6.2
- Introduce a configurable median filter for the lock feedback
- Fixed reading HW variant from EEPROM
- Bidirectional power transfer: more adapted contactors handling
- Fixed race condition during AC ending charge affecting lock state check
- ccs-evcc 2.7.0
- Improved MCS sequence: wait for contactors to open at the end of ending charge phase and before setting CE state B
- advantics-csm 1.7.2
- Add the new config parameters
- Add dig_out options in the UI
|
Download link: evcc-release-2.7.1.zip |
| release 2.6.1 |
2026-04-14 |
- ccs-evcc 2.6.1
- Fixed EVCC ID not read correctly from config file
|
Download link: evcc-release-2.6.1.zip |
| release 2.6 |
2026-04-10 |
- pev-controller 2.5.0
- Fixed onefile mode folders not getting cleared properly on power cycle
- Added advanced E-stop contactor handling options for unreliable current measurements
- ccs-evcc 2.6.0
- Fixed onefile mode folders not getting cleared properly on power cycle
- advantics-csm 1.7.1
- Fix temperature config section
- Bring back controller type to header
- Add CSM version on footer
- Migrate from remix to react router 7
|
Download link: evcc-release-2.6.zip |
| release 2.5 |
2026-03-13 |
- pev-controller 2.4.0
- Fixed checking DC contactors state and DC messages during emergency while AC charging
- Fixed inputs message being sent with wrong values before initialization completes (startup race condition)
- Contactors opening: raised the current-below-limit threshold to 5 A; added a configurable timeout after which contactors open unconditionally if current doesn't drop below limit
- Startup safety: inputs messages are now suppressed until hardware I/O initialization is fully complete
- Temperature: median filter is now applied to temperature sensor inputs
- GC performance: persistent objects are now untracked from the garbage collector to reduce GC overhead
- ccs-evcc 2.5.0
- Fixed bug where frontend did not send Closing_Communication stage to backend in EmergencyShutdownState
- Moved CP state reporting to the PLC reading level to eliminate wrong-state reports
- Fixed alarm cancelled more than once on protocol reset (cancel only once per exit)
- bcb_toggle_detected called from unexpected states now handled gracefully (no-op)
- Skip CP filtering while resuming a paused session, to correctly detect the B1→B2 transition
- Allow session resume only when the previous session is fully over
- advantics-csm 1.7.0
- Fix logic while exporting logs, server would respond with error code and nothing attached
- Add the ability to generate sample config for every controller
- Fix dynamic voltage meter bar in monitoring and use kW for power metering instead of W
- Remove unused items from navigation side bar
- Minor improvements
|
Download link: evcc-release-2.5.zip |
| release 2.4.1 |
2025-12-23 |
- ccs-evcc 2.4.1
- Bug fix: checking for wrong CP state in session stop state resulting in abnormal session termination in some cases
- advantics-csm 1.6.4
|
Download link: evcc-23-12-2025.zip |
| release 2.4 |
2025-12-11 |
- pev-controller 2.3.0
- Add possibility of dynamic target voltage control (configurable)
- Allow bidirectional cycling at full SOC (configurable)
- Disable current deviation check against target current in range mode (dynamic mode)
- ccs-evcc 2.4.0
- Possibility to disable AC charging (configurable) (only relevant for CCS)
- Pause and resume session according to ISO15118-2 and ISO15118-20
- advantics-csm 1.6.3
- Add the possibility to restart CSM when submitting config from the UI
- Toggle J1939/CAN monitoring on config change without restarting the whole app
- Support both extendend and non-extended IDs for CAN monitoring
|
Download link: evcc-11-12-2025.zip |
| release 2.3 |
2025-09-15 |
- pev-controller 2.2.5
New CAN bus message EVCC_MEVC_Diagnostic_Status: Diagnostic status of the charge controller:- Shows active faults and errors detected by the charge controller.
- Status signals received from the charger over High-Level Communication (HLC).
- ccs-evcc 2.3.5
- Send HLC error codes and forward charger status signals received over High-Level Communication (HLC).
- Fix minor bug in ServiceDiscovery in handling extra services.
- advantics-csm 1.5.4
- Fix log exporting issue; improve logging page experience (docker socket starvation, app status in colors).
- Add export config file in config page.
- Add J1939 capabilities; QOL improvements for J1939 logging.
- Fix management page for EVCC (official support of EVCC).
- Add error stack to monitoring page.
- Fix UI typos and descriptions.
|
Download link: evcc-15-09-2025.zip |
| release 2.2 |
2025-08-04 |
- pev-controller 2.2.4
- New CAN bus signal HV_Preparing_Hold_Off:
Allow the vehicle to delay the transition to powered states (starting from the insulation test) until the HV system is ready. - Advantics_Generic_PEV_protocol_v2: Expand energy limits and revise signal slopes accordingly.
- ccs-evcc 2.3.3
- Allow the vehicle to delay the transition to powered states (starting from the insulation test) until the HV system is ready.
|
Download link: evcc-04-08-2025.zip |
| release 2.1 |
2025-07-23 |
- pev-controller 2.2.3
- fix PEV temperature: add support for temperature monitoring
- allow contactor feedback via CAN bus while contactor control is done via IOs
- allow LEDs control via CAN bus interface
- advantics-csm 1.4.2
- extend config interface
- fix bug in SW update process on management interface.
|
Download link: evcc-23-07-2025.zip |
| release 2.0 |
2025-07-07 |
- New Application:
- advantics-csm: Advantics CSM, short for Advantics Controller System Manager, handles all system-level operations.
It provides a web interface for monitoring and configuring the system, minimizing the need for manual config file edits and command-line interactions. Users can access logs, manage applications, and perform system updates directly through the interface (CSM Web UI).
- pev-controller 2.2.2
- fix for re-entering emergency state when no_inlet_lock and contactors open CAN message not fast enough
- ccs-evcc 2.3.2
- Plug and Charge support
- Fix calling GC by reset_cache causing nodes disconnection (which also asserts interlock).
|
Download link: pev-release-2.0.zip |
| Release 2024-10-15 |
2024-10-15 |
ISO15118-20 BPT: Use CAN message to dynamically update current limits |
pev-2024-10-15.tar |
| Bidirectional dev |
2022-11-17 |
ISO 15118-20 Generic CAN interface v2 |
Snapshot |
| release 1.0 |
2022-11-25 |
Changelog |
- |
| 2.0.0rc3 |
2022-11-03 |
Prefigure rc3 |
Snapshot |
| 2.0.0rc2 |
2021-06-11 |
Changelog |
ADM-CS-EVCC (Gen3) |
| 2.0.0rc1 |
2021-02-04 |
Changelog |
ADM-CS-EVCC (Gen3) |
| 2019-06-11--001 |
2019-06-11 |
Changelog |
ADM-CS-EVCC (Gen2) ADM-CO-CUI1 |
| 2018-09-25--001 |
2018-09-25 |
ADM-CO-CUI1 |
- |