The ADM-CS-EVCC is an electric vehicle subsystem. It cannot function on its own, but when integrated in a vehicle, it will provide AC and DC charging abstraction through a simple CAN bus interface. Thanks to charge inlet monitoring and control, as well as DC contactor control, very little is required from the vehicle to get the system up and running.

Power input¶
The controller expects 12V or 24V power. It is designed to handle the typical environment of automotive 12/24V systems. For user convenience, it is possible to use for example 12V contactors/inlets in a 24V system, as the contactor drivers are powered from a separate input.
Consult the specifications sheet for current requirements.
CCS and AC interfaces¶
The CCS and AC interfaces consist of CP and PP lines, inlet lock and temperature sensor inputs. All of these signals are fully controlled by the communication stack – the user does not have to interact with them in any way. They simply need to be wired properly to the inlet cable.
Tip
There are many different CCS and AC inlets and cables. Suitable cables are manufactured by typical suppliers such as Phoenix Contact, and are available in a wide price-range. However, beware of potential wiring differences. Consult your choice of cable with ADVANTICS.
Inlet locking¶
The CCS inlet contains a motorized locking mechanism, designed to prevent removal of the cable during the charging cycle (when hazardous voltages can be present), and to prevent cable theft. The inlet lock motor is a simple DC motor, driving a locking pin. For proper operation, 12V (or 24V) is being applied in different polarities to the DC motor to push pin into the inlet, or to extract it.
Loss of power
In the case of power loss or charger/vehicle failure, all inlet locking mechanisms come with a manual release lever. This lever is accessible from the inside of the vehicle – typically accessed by removing carpet on the side in the trunk. Do not use the manual release during operation – only in case of emergencies.
Temperature monitoring¶
The CCS inlet comes with integrated PT1000 temperature sensors. They should be directly connected to the EVCC. During high current charging, it is possible to encounter dangerous temperatures (especially if the inlet or cable is damaged). The EVCC will shut down the charging cycle in case limits are exceeded.
CHAdeMO interface – NOT USED¶
The ADM-CS-EVCC hardware comes with CHAdeMO inlet as well. But the software does not support this interface. Since most newly produced vehicles and charging stations only come with CCS support, it is very likely that the CHAdeMO interface will never be implemented, so it is kept in the manual only for pinout reference.
DC fast charge contactors control¶
The charge controller has two independent outputs for controlling the positive and negative fast charge DC contactors. Also there is an extra digital input for each one of them, for potential welding detection (provided that the contactors have auxiliary contacts built-in).
The purpose of these contactors is to ‘expose’ the vehicle battery to the charger during fast charging. Fast charging effectively bypasses the onboard charger in the vehicle, and instead allows the charging station direct access to the battery. In order for this operation to be safe, a few conditions must be met. In simple terms, the charger and car will first negotiate required voltage and current, perform internal tests (like insulation test), followed by a precharge request. During precharge, the EV requests the charger to supply a voltage matching the battery voltage. The vehicle will continuously monitor the inlet voltage, and when the charger reaches the requested voltage, the charge controller will close the DC fast charge contactors.
The last feature of the DC contactor control is external power input. This input needs to be wired to a power supply (typically a battery) capable of sourcing enough current for the contactors to operate. In most applications, the CONTACTOR_POWER pin will simply be wired to the same supply as the main power input. The only reason for it to be wired in a different way is to allow mixed 12V and 24V operation (24V trucks using 12V contactors, for example).
CCS sequence tip
The CharIN CCS guide mentioned at the beginning of this document describes clearly the mating process and sequencing. It is highly recommended to read this guide.
Vehicle CAN bus¶
The charge controller has one dedicated CAN bus for the integration with the vehicle. The customer is expected to provide the controller with the necessary information over CAN bus, for the charging to work properly. The EVCC will report useful/necessary information about the charge process itself.
The CAN bus runs at a speed of 500 kbaud by default. There is no 120 Ohm termination on this bus by default, but it can be easily enabled by switching the DIP switch on the PCB into ON position. This will connect a 120 Ohm termination resistor between CAN high and low. There should only be 2 terminations on the CAN bus – ideally on both end-points of the CAN chain.

CAN bus tip
If you don’t see all the CAN messages you were expecting on the bus, the periodicity is wrong, or no messages are shown at all, the CAN bus termination could be missing. CAN bus should have two terminations, but on the bench will also typically work with just one, or three.
Charge stop¶
The charge stop input allows users to terminate the charging in a clean way – by using a (user operated) push button for example. It behaves as if the charger side was requesting a normal stop.
The Charge stop input should be pulled up to trigger a stop request
It is also possible to terminate the charge over the CAN bus.
Digital inputs and outputs¶
There are two digital inputs and three digital outputs on the charge controller. The digital inputs and outputs are fully user-configurable and controllable (provided the user writes an application for their control).
Digital Outputs¶
The outputs are push-pull capable, supplied from the input power of the controller (so are either 12V or 24V). Can be used to drive loads up to 100mA.
For GPIO control, please refer to sections Manual GPIO control and GPIO control in your application
Digital Inputs¶
The inputs are 24V tolerant but are also compatible with 12V logic level, the maximum voltage on this pin is about 30V, and have a weak 10 kOhm pulldown. Transition to ‘1' from 9V sets the input to ON. It will then hold '1’ until the voltage drops under 3V.
LED outputs¶
LED outputs are powered from CCS lock power (so they share the same voltage level). A high side drivers are used, with a current limit of 100mA per channel. LEDs are fully user configurable and controllable, and can be used for to power other loads (as long as limits are not exceeded).
Ethernet¶
During R&D, Ethernet can be used to deploy FW and communicate with the unit. The RJ45 connector is located on the opposite side from the main connector, and is inaccessible once the box is closed. Consult the SW Development Manual for how to work with the system over an SSH connection.
Requirement for inlet monitoring¶
To be compliant with the CCS standards, the vehicle must contain voltage sensors for monitoring of the inlet DC pins, a current sensor for measuring the charge current, and a battery voltage monitoring.
Warning
It is not sufficient to just measure the HV battery voltage. The user MUST monitor the inlet voltage, as there are DC contactors separating the battery from the inlet when not charging (so the battery voltage does not equal inlet voltage!).
For simplicity of wiring, the user can install a combined voltage and current sensor, such as the Isabellenhutte IVT-S. The sensor should simultaneously monitor the battery voltage, the inlet voltage as well as charging current. Depending on the target charging current, For example IVT-S-300-U3-I-CAN2-12/24 model (300A, 3 voltage sensors, no CAN termination, isolated) can be used. ADVANTICS supplies the IVT-S-1k-U3-I-CAN2-12/24 model, as the same unit can be used for higher current applications (like main battery current sensor), and the loss of resolution with higher current full-scale is not critical in this application.