Skip to content

CAN messages

Generated from Advantics Generic PEV protocol 2.5 (Advantics_Generic_PEV_protocol_v2.5.kcd).

Message index

Name ID Length Direction Cycle time
EVSE_Information 0x600 6 OUT 100
AC_Control 0x601 1 OUT 100
DC_Control 0x602 1 OUT 100
CCS_Extra_Information 0x603 6 OUT 100
ADM_CS_EVCC_Inputs 0x604 6 OUT 1000
EVCC_MEVC_Diagnostic_Status 0x605 8 OUT 100
MCS_Extra_Information 0x606 8 OUT 100
EV_Information 0x610 3 IN 100
AC_Status 0x611 1 IN 100
DC_Status1 0x612 8 IN 100
DC_Status2 0x613 5 IN 100
EV_Energy_Request 0x614 6 IN 100
EV_V2X_Energy_Request 0x615 4 IN 100
EV_Extra_BPT_Information 0x616 4 IN 100
ADM_CS_EVCC_MEVC_Outputs 0x617 8 IN
EV_Status 0x618 8 IN

EVSE_Information

* *
Frame ID 0x600
Length [Bytes] 6
Periodicity [ms] 100
Direction OUT

Description

Information about the EVSE (AC or DC source), when available.

Payload

Signal Length (bits) Type
Communication_Stage 8 Label set
Protocol 8 Label set
Pins 8 Label set
Max_Current 16 Signed
RCD_Status 1 Label set
Reserved_Flags 7 Unsigned

Payload description

Communication_Stage

Current internal state of the charge controller, reflecting communication stage.

Initialising

Controller's applications are starting up.

Waiting For EVSE

Controller is idle and ready for a plug-in.

Negotiating Connection

Controller is plugged to a charger and the connection is being initialised. Important charge information are exchanged.

Connected With Full Info

All charge information from the EVSE were retrieved and a charge session can be considered to be properly started.

Insulation Test

Insulation of charge cable is being tested by charger.

Precharge

Charger is matching its output voltage to present voltage of the battery.

Waiting For Charge

PEV is about to begin the actual charge.

Charging

Main charging loop going on.

Ending Charge

A normal charge stop condition happened and the PEV is exiting the charging loop.

Welding Detection

PEV is testing if its contactors are welded.

Closing Communication

PEV can unplug and we are reinitialising in order to then go back to Waiting_For_EVSE.

Start bit Length (bits) Type Unit Scale Offset Min Max
0 8 Label set 1 0
Label name Value
Initialising 0
Waiting_For_EVSE 1
Negotiating_Connection 2
Connected_With_Full_Info 3
Insulation_Test 4
Precharge 5
Waiting_For_Charge 6
Charging 7
Ending_Charge 8
Welding_Detection 9
Closing_Communication 10
Charge_Pause 11

Protocol

The charging protocol EVSE is using.

Start bit Length (bits) Type Unit Scale Offset Min Max
8 8 Label set 1 0
Label name Value
0
CCS_PWM 1
CCS_DIN_70121_2012_v2 2
CCS_ISO_15118_2013_v2 3
CCS_ISO_15118_2022 4

Pins

Pins on which current is supplied. CCS_AC corresponds to any AC pins.

Start bit Length (bits) Type Unit Scale Offset Min Max
16 8 Label set 1 0
Label name Value
0
CCS_AC 1
CCS_AC_Single_Phase_Core 2
CCS_AC_Three_Phase_Core 3
CCS_DC_Core 4
CCS_DC_Extended 5
MCS 6

Max_Current

Maximum current the on-board charger (AC) or BMS (DC) is allowed to draw.

In AC, it is defined as the minimum between EVSE max current (ie. CP PWM duty cycle) and cable max current (ie. PP resistance).

In DC it corresponds to HLC data.

Start bit Length (bits) Type Unit Scale Offset Min Max
24 16 Signed Amps 1 0 -32768 32767

RCD_Status

Status of EVSE Residual Current Device (only available in HLC mode, 0 otherwise). For information only.

Start bit Length (bits) Type Unit Scale Offset Min Max
40 1 Label set 1 0
Label name Value
No_Error 0
Error 1

Reserved_Flags

Reserved bits for future uses.

Start bit Length (bits) Type Unit Scale Offset Min Max
41 7 Unsigned 1 0

AC_Control

* *
Frame ID 0x601
Length [Bytes] 1
Periodicity [ms] 100
Direction OUT

Description

AC charging specific control (from charge controller to on-board charger).

Payload

Signal Length (bits) Type
Ready_To_Deliver_Power 1 Label set
Reserved_Flags 7 Unsigned

Payload description

Ready_To_Deliver_Power

EVSE is in position of delivering power.

Warning

Does not mean that power is currently being delivered!

When going to Ready, the on-board charger should set its AC_Status.Ready_To_Charge flag, and THEN start to draw current.

When going to Not_Ready it means the AC source request a normal stop. On-board charger should stop drawing current and THEN set its AC_Status.Ready_To_Charge flag to 0.

Start bit Length (bits) Type Unit Scale Offset Min Max
0 1 Label set 1 0
Label name Value
Not_Ready 0
Ready 1

Reserved_Flags

Reserved bits for future uses.

Start bit Length (bits) Type Unit Scale Offset Min Max
1 7 Unsigned 1 0

DC_Control

* *
Frame ID 0x602
Length [Bytes] 1
Periodicity [ms] 100
Direction OUT

Description

DC charging specific control (from charge controller to BMS).

Payload

Signal Length (bits) Type
Close_Contactors 1 Label set
Reserved_Flags 7 Unsigned

Payload description

Close_Contactors

Request for closing contactors. Close contactors when 1. Open them when 0. If the message does not come after 1s timeout, consider it to be an emergency situation and open contactors.

Alternatively, ADM-CS-EVCC unit has DC contactor drivers. To use them directly instead of this CAN signal, enable them in the /srv/config.cfg file:

[vehicle]
dc_contactors_use_ios = true
Start bit Length (bits) Type Unit Scale Offset Min Max
0 1 Label set 1 0
Label name Value
Open 0
Close 1

Reserved_Flags

Reserved bits for future uses.

Start bit Length (bits) Type Unit Scale Offset Min Max
1 7 Unsigned 1 0

CCS_Extra_Information

* *
Frame ID 0x603
Length [Bytes] 6
Periodicity [ms] 100
Direction OUT

Description

Extra information from CCS (for information only).

Payload

Signal Length (bits) Type
CP_Duty_Cycle 16 Unsigned
CP_Top_Voltage 8 Unsigned
CP_State 8 Label set
PP_Resistance 8 Unsigned
Inlet_Lock_State 2 Label set
Reserved_Flags 6 Unsigned

Payload description

CP_Duty_Cycle

Measured PWM duty cycle on the CP line.

Start bit Length (bits) Type Unit Scale Offset Min Max
0 16 Unsigned % 0.1 0 0 100

CP_Top_Voltage

Measured PWM top voltage on the CP line.

Start bit Length (bits) Type Unit Scale Offset Min Max
16 8 Unsigned Volts 0.1 0

CP_State

Measured CP state.

Start bit Length (bits) Type Unit Scale Offset Min Max
24 8 Label set 1 0
Label name Value
E_or_F 0
D 3
C 6
B 9
A 12

PP_Resistance

Measured resistance from PP. 2550 Ohms means disconnected.

Start bit Length (bits) Type Unit Scale Offset Min Max
32 8 Unsigned Ohms 10 0 0 2550

Inlet_Lock_State

CCS Inlet lock state.

Start bit Length (bits) Type Unit Scale Offset Min Max
40 2 Label set 1 0
Label name Value
Unlocked 0
Locked 1
Fault 2

Reserved_Flags

Reserved bits for future uses.

Start bit Length (bits) Type Unit Scale Offset Min Max
42 6 Unsigned 1 0

ADM_CS_EVCC_Inputs

* *
Frame ID 0x604
Length [Bytes] 6
Periodicity [ms] 1000
Direction OUT

Description

Controller (ADM-CS-EVCC hardware variant) is reporting various information about its inputs. It is sent every seconds (for temperature channels). Or on change for other digital inputs.

Payload

Signal Length (bits) Type
DC_Contactor_Positive_Feedback 1 Label set
DC_Contactor_Negative_Feedback 1 Label set
Digital_Input1 1 Single bit
Digital_Input2 1 Single bit
Stop_Charge 1 Label set
Reserved_Flags 3 Unsigned
PTC0 8 Unsigned
PTC1 8 Unsigned
PTC2 8 Unsigned
CPU_Temperature 8 Unsigned
CAN_Sensor_Temperature 8 Unsigned

Payload description

DC_Contactor_Positive_Feedback

Reports the logical state of R-2E.

Start bit Length (bits) Type Unit Scale Offset Min Max
0 1 Label set 1 0
Label name Value
Open 0
Close 1

DC_Contactor_Negative_Feedback

Reports the logical state of R-2F.

Start bit Length (bits) Type Unit Scale Offset Min Max
1 1 Label set 1 0
Label name Value
Open 0
Close 1

Digital_Input1

Reports the logical state of R-1G. Needs to be declared as monitored in /srv/config.cfg:

[hardware]
dig_in1 = Monitor
Start bit Length (bits) Type Unit Scale Offset Min Max
2 1 Single bit 1 0 0 1

Digital_Input2

Reports the logical state of R-2G. Needs to be declared as monitored in /srv/config.cfg:

[hardware]
dig_in2 = Monitor
Start bit Length (bits) Type Unit Scale Offset Min Max
3 1 Single bit 1 0 0 1

Stop_Charge

Reports the logical state of R-3F (or any other input declared as Stop function).

Start bit Length (bits) Type Unit Scale Offset Min Max
4 1 Label set 1 0
Label name Value
No_Request 0
Stop_Requested 1

Reserved_Flags

Reserved bits for future uses.

Start bit Length (bits) Type Unit Scale Offset Min Max
5 3 Unsigned 1 0

PTC0

Measured temperature sensor on L-2D.

Start bit Length (bits) Type Unit Scale Offset Min Max
8 8 Unsigned °C 1 -40 -40 215

PTC1

Measured temperature sensor on L-1E.

Start bit Length (bits) Type Unit Scale Offset Min Max
16 8 Unsigned °C 1 -40 -40 215

PTC2

Measured temperature sensor on L-3E.

Start bit Length (bits) Type Unit Scale Offset Min Max
24 8 Unsigned °C 1 -40 -40 215

CPU_Temperature

Temperature reported by the CPU chip of the charge controller.

Start bit Length (bits) Type Unit Scale Offset Min Max
32 8 Unsigned °C 1 -40 -40 215

CAN_Sensor_Temperature

If using a CAN sensor, and it has a temperature channel.

Start bit Length (bits) Type Unit Scale Offset Min Max
40 8 Unsigned °C 1 -40 -40 215

EVCC_MEVC_Diagnostic_Status

* *
Frame ID 0x605
Length [Bytes] 8
Periodicity [ms] 100
Direction OUT

Description

Info

Available since version 2.3

Diagnostic status of the charge controller. This message gets reset to default values when the controller the state cycles back to Communication_Stage.Waiting_For_EVSE

Payload

Signal Length (bits) Type
LockFailure 1 Single bit
UnlockDeclinedInletEnergized 1 Single bit
HighTemperature 1 Single bit
ContactorFault 1 Single bit
VoltageDeviation 1 Single bit
CurrentDeviation 1 Single bit
PrechargeTimeout 1 Single bit
ProximityPilotNotDetected 1 Single bit
InsertionDetectionNotDetected 1 Single bit
ControlPilotFault 1 Single bit
ChargeEnableFault 1 Single bit
ControlPilotDutyCycleUnexpected 1 Single bit
ControlPilotStateUnexpected 1 Single bit
ChargeEnableStateUnexpected 1 Single bit
ControlPilotStateNotSupported 1 Single bit
PLCFault 1 Single bit
V2GTPTLSError 1 Single bit
V2GTPAuthorizationFailure 1 Single bit
V2GTPServiceSelectionFailure 1 Single bit
V2GTPProtocolVersionInvalid 1 Single bit
V2GTPSessionIDUnexpected 1 Single bit
V2GTPPayloadInvalid 1 Single bit
V2GTPEnergyTransferModeNotSupported 1 Single bit
V2GTPSequenceError 1 Single bit
V2GTPSequenceTimeout 1 Single bit
SDPError 1 Single bit
Reserved_Flags 22 Unsigned
HLC_ResponseCode 8 Label set
EVSE_StatusCode 4 Label set
EVSE_Isolation_Level 4 Label set

Payload description

LockFailure

Indicates a failure in locking the connector.

Start bit Length (bits) Type Unit Scale Offset Min Max
0 1 Single bit 1 0

UnlockDeclinedInletEnergized

Unlock request declined due to voltage/current measured at the inlet.

Start bit Length (bits) Type Unit Scale Offset Min Max
1 1 Single bit 1 0

HighTemperature

Error due to high temperature detected.

Start bit Length (bits) Type Unit Scale Offset Min Max
2 1 Single bit 1 0

ContactorFault

Indicates a contactor fault. Can also be caused by wrong wiring or configuration of contactor feedbacks.

Start bit Length (bits) Type Unit Scale Offset Min Max
3 1 Single bit 1 0

VoltageDeviation

Voltage deviation detected beyond allowed limits.

Start bit Length (bits) Type Unit Scale Offset Min Max
4 1 Single bit 1 0

CurrentDeviation

Current deviation detected beyond allowed limits.

Start bit Length (bits) Type Unit Scale Offset Min Max
5 1 Single bit 1 0

PrechargeTimeout

Precharge process did not complete within the expected time.

Start bit Length (bits) Type Unit Scale Offset Min Max
6 1 Single bit 1 0

ProximityPilotNotDetected

CCS PP signal not detected.

Start bit Length (bits) Type Unit Scale Offset Min Max
7 1 Single bit 1 0

InsertionDetectionNotDetected

MCS ID signal not detected.

Start bit Length (bits) Type Unit Scale Offset Min Max
8 1 Single bit 1 0

ControlPilotFault

Fault detected on the CCS CP line.

Start bit Length (bits) Type Unit Scale Offset Min Max
9 1 Single bit 1 0

ChargeEnableFault

Fault detected in MCS CE line.

Start bit Length (bits) Type Unit Scale Offset Min Max
10 1 Single bit 1 0

ControlPilotDutyCycleUnexpected

Unexpected duty cycle detected on CCS CP line.

Start bit Length (bits) Type Unit Scale Offset Min Max
11 1 Single bit 1 0

ControlPilotStateUnexpected

Unexpected state detected on CCS CP line.

Start bit Length (bits) Type Unit Scale Offset Min Max
12 1 Single bit 1 0

ChargeEnableStateUnexpected

Unexpected state detected in MCS CE line.

Start bit Length (bits) Type Unit Scale Offset Min Max
13 1 Single bit 1 0

ControlPilotStateNotSupported

CCS CP state not supported by the system.

Start bit Length (bits) Type Unit Scale Offset Min Max
14 1 Single bit 1 0

PLCFault

Power Line Communication (PLC) fault detected. This is a generic flag, for more specific information (when available) refer to the V2GTP* flags below.

Start bit Length (bits) Type Unit Scale Offset Min Max
15 1 Single bit 1 0

V2GTPTLSError

V2GTP TLS error occurred during communication.

Start bit Length (bits) Type Unit Scale Offset Min Max
16 1 Single bit 1 0

V2GTPAuthorizationFailure

V2GTP authorization process failed.

Start bit Length (bits) Type Unit Scale Offset Min Max
17 1 Single bit 1 0

V2GTPServiceSelectionFailure

V2GTP service selection failed.

Start bit Length (bits) Type Unit Scale Offset Min Max
18 1 Single bit 1 0

V2GTPProtocolVersionInvalid

Invalid V2GTP protocol version detected.

Start bit Length (bits) Type Unit Scale Offset Min Max
19 1 Single bit 1 0

V2GTPSessionIDUnexpected

Unexpected V2GTP session ID encountered.

Start bit Length (bits) Type Unit Scale Offset Min Max
20 1 Single bit 1 0

V2GTPPayloadInvalid

Invalid payload detected in V2GTP communication.

Start bit Length (bits) Type Unit Scale Offset Min Max
21 1 Single bit 1 0

V2GTPEnergyTransferModeNotSupported

V2GTP energy transfer mode not supported.

Start bit Length (bits) Type Unit Scale Offset Min Max
22 1 Single bit 1 0

V2GTPSequenceError

Sequence error detected in V2GTP communication.

Start bit Length (bits) Type Unit Scale Offset Min Max
23 1 Single bit 1 0

V2GTPSequenceTimeout

Timeout occurred in V2GTP sequence.

Start bit Length (bits) Type Unit Scale Offset Min Max
24 1 Single bit 1 0

SDPError

Service Discovery Protocol (SDP) error detected.

Start bit Length (bits) Type Unit Scale Offset Min Max
25 1 Single bit 1 0

Reserved_Flags

Reserved bits for future uses.

Start bit Length (bits) Type Unit Scale Offset Min Max
26 22 Unsigned 1 0

HLC_ResponseCode

High-Level Communication (HLC) response codes for EVSE communication protocols.

Start bit Length (bits) Type Unit Scale Offset Min Max
48 8 Label set 1 0
Label name Value
Undefined 0
OK 1
OK_CertificateExpiresSoon 2
OK_NewSessionEstablished 3
OK_OldSessionJoined 4
OK_PowerToleranceConfirmed 5
WARNING_AuthorizationSelectionInvalid 6
WARNING_CertificateExpired 7
WARNING_CertificateNotYetValid 8
WARNING_CertificateRevoked 9
WARNING_CertificateValidationError 10
WARNING_ChallengeInvalid 11
WARNING_EIMAuthorizationFailure 12
WARNING_eMSPUnknown 13
WARNING_EVPowerProfileViolation 14
WARNING_GeneralPnCAuthorizationError 15
WARNING_NoCertificateAvailable 16
WARNING_NoContractMatchingPCIDFound 17
WARNING_PowerToleranceNotConfirmed 18
WARNING_ScheduleRenegotiationFailed 19
WARNING_StandbyNotAllowed 20
WARNING_WPT 21
FAILED 22
FAILED_AssociationError 23
FAILED_ContactorError 24
FAILED_EVPowerProfileInvalid 25
FAILED_EVPowerProfileViolation 26
FAILED_MeteringSignatureNotValid 27
FAILED_NoEnergyTransferServiceSelected 28
FAILED_NoServiceRenegotiationSupported 29
FAILED_PauseNotAllowed 30
FAILED_PowerDeliveryNotApplied 31
FAILED_PowerToleranceNotConfirmed 32
FAILED_ScheduleRenegotiation 33
FAILED_ScheduleSelectionInvalid 34
FAILED_SequenceError 35
FAILED_ServiceIDInvalid 36
FAILED_ServiceSelectionInvalid 37
FAILED_SignatureError 38
FAILED_UnknownSession 39
FAILED_WrongChargeParameter 40
FAILED_PaymentSelectionInvalid 41
FAILED_CertificateExpired 42
FAILED_CertChainError 43
FAILED_ChallengeInvalid 44
FAILED_ContractCanceled 45
FAILED_TariffSelectionInvalid 46
FAILED_ChargingProfileInvalid 47
FAILED_NoChargeServiceSelected 48
FAILED_WrongEnergyTransferMode 49
FAILED_CertificateNotAllowedAtThisEVSE 50
FAILED_CertificateRevoked 51
FAILED_EVSEPresentVoltageToLow 52
FAILED_WrongEnergyTransferType 53

EVSE_StatusCode

Only relevant for DIN SPEC 70121 and ISO 15118-2 protocols. (was removed in ISO 15118-20)

Start bit Length (bits) Type Unit Scale Offset Min Max
56 4 Label set 1 0
Label name Value
Undefined 0
EVSE_NotReady 1
EVSE_Ready 2
EVSE_Shutdown 3
EVSE_UtilityInterruptEvent 4
EVSE_IsolationMonitoringActive 5
EVSE_EmergencyShutdown 6
EVSE_Malfunction 7
Invalid 8

EVSE_Isolation_Level

Only relevant for DIN SPEC 70121 and ISO 15118-2 protocols. (was removed in ISO 15118-20)

Start bit Length (bits) Type Unit Scale Offset Min Max
60 4 Label set 1 0
Label name Value
Undefined 0
Invalid 1
Valid 2
Warning 3
Fault 4
No_IMD 5

MCS_Extra_Information

* *
Frame ID 0x606
Length [Bytes] 8
Periodicity [ms] 100
Direction OUT

Description

Extra information from MCS (for information only).

Payload

Signal Length (bits) Type
CE_State 8 Label set
ID_State 8 Label set
Reserved_Flags 48 Unsigned

Payload description

CE_State

Measured CE state.

Start bit Length (bits) Type Unit Scale Offset Min Max
0 8 Label set 1 0
Label name Value
Undefined 0
A 1
B0 2
B0_Aux 3
B 4
B_Aux 5
C 6
C_Aux 7
EC 8
E 9

ID_State

Measured ID state.

Start bit Length (bits) Type Unit Scale Offset Min Max
8 8 Label set 1 0
Label name Value
Undefined 0
Inlet_Not_Present 1
Unmated 2
Mated_NoEVSE 3
Mated_EVSE 4
Mated_EVAux 5
Mated_EVSEAux 6

Reserved_Flags

Reserved bits for future uses.

Start bit Length (bits) Type Unit Scale Offset Min Max
16 48 Unsigned 1 0

EV_Information

* *
Frame ID 0x610
Length [Bytes] 3
Periodicity [ms] 100
Direction IN

Description

Information provided by the vehicle.

Payload

Signal Length (bits) Type
State_of_Charge 8 Unsigned
Energy_Capacity 16 Unsigned

Payload description

State_of_Charge

Battery SoC in percent (only used in HLC mode).

Start bit Length (bits) Type Unit Scale Offset Min Max
0 8 Unsigned % 1 0 0 100

Energy_Capacity

The energy capacity of the EV battery. In case this value is 0 we default to the config file entry energy_capacity.

Please note that providing the energy capacity of the battery is mandatory if ISO15118-20 is used.

Start bit Length (bits) Type Unit Scale Offset Min Max
8 16 Unsigned kWh 0.1 0 0 6553

AC_Status

* *
Frame ID 0x611
Length [Bytes] 1
Periodicity [ms] 100
Direction IN

Description

AC charging specific status (from on-board charger to charge controller).

Payload

Signal Length (bits) Type
Ready_To_Charge 1 Label set
Reserved_Flags 7 Unsigned

Payload description

Ready_To_Charge

On-board charger is ready to charge (corresponds to asserting CP state C/D). You should set it to 1 before starting to draw current. And set it to 0 after current draw stops.

Only exception is in case of emergency stop, where you can set it to 0 without waiting for the current draw to stop beforehand.

Start bit Length (bits) Type Unit Scale Offset Min Max
0 1 Label set 1 0
Label name Value
Not_Ready 0
Ready 1

Reserved_Flags

Reserved bits for future uses.

Start bit Length (bits) Type Unit Scale Offset Min Max
1 7 Unsigned 1 0

DC_Status1

* *
Frame ID 0x612
Length [Bytes] 8
Periodicity [ms] 100
Direction IN

Description

DC charging specific status (from BMS to charge controller), message 1.

Payload

Signal Length (bits) Type
Max_Charge_Current 16 Signed
Present_Current 16 Signed
Max_Discharge_Current 16 Unsigned
Target_Voltage 16 Unsigned

Payload description

Max_Charge_Current

Used as the target current sent to EVSE except for power transfer with CCS ISO15118-20 Dynamic mode, this signal will be used as the EV Maximum charge current. Note that negative values will be disregarded in CCS ISO 15118-20 Dynamic mode.

This signal can be dynamically updated by the BMS to limit the charge current

Will be capped by maximum current from config file and from EVSE data.

When in No BMS mode, the target current will be set to the config file entry "max_current". When doing so, you should set a safe max_charge_voltage to terminate the charge earlier than at full pack (ie. bulk charging):

[vehicle]
no_bms = true
max_current = 20
max_charge_voltage = 380
target_voltage = 410
max_voltage = 450

In no BMS mode, this signal will be ignored.

Note

Signal is of signed data type for compatibility with future bidirectional implementations.

Start bit Length (bits) Type Unit Scale Offset Min Max
0 16 Signed Amps 1 0 -32768 32767

Present_Current

Measurement of current flowing in or out of the battery.

Alternatively, this information can be obtained by using a supported CAN sensor. Declare it as such in /srv/config.cfg:

[vehicle]
use_can_sensor = Isabellenhutte IVT-S

In such case, this signal will be ignored. Refer to CAN sensor documentation to know how the sensor should be wired.

Note

Signal is of signed data type for compatibility with future bidirectional implementations.

Start bit Length (bits) Type Unit Scale Offset Min Max
16 16 Signed Amps 1 0 -32768 32767

Max_Discharge_Current

Only taken into account in CCS ISO15118-20 Dynamic mode. This signal can be used to dynamically update the EV Maximum Discharge current.

This signal can be dynamically updated by the BMS to limit the discharge current

Note that negative values will be disregarded. Will be capped by max_discharge_current from config file.

Start bit Length (bits) Type Unit Scale Offset Min Max
32 16 Unsigned Amps 1 0 0 65535

Target_Voltage

Info

Available since version 2.4

Allows dynamic target voltage updates. Will be capped by maximum voltage from config file and from EVSE data. Only taken into account when the config entry dynamic_target_voltage is set to true. Declare it as such in /srv/config.cfg:

[vehicle]
dynamic_target_voltage = True

Note 1: If the config entry dynamic_target_voltage is set to true, and this signal is set to 0, the value defined in the config entry target_voltage will be used instead.

Note 2: If the config entry dynamic_target_voltage is set to false, this signal will be ignored. The value defined in the config entry target_voltage will be used instead.

Start bit Length (bits) Type Unit Scale Offset Min Max
48 16 Unsigned Volts 1 0 0 65535

DC_Status2

* *
Frame ID 0x613
Length [Bytes] 5
Periodicity [ms] 100
Direction IN

Description

DC charging specific status (from BMS to charge controller), message 2.

Payload

Signal Length (bits) Type
Contactors_Closed 1 Label set
Normal_End_of_Charge 1 Label set
Emergency_Stop 1 Label set
Reserved_Flags 5 Unsigned
Battery_Voltage 16 Unsigned
Inlet_Voltage 16 Unsigned

Payload description

Contactors_Closed

Report states of contactors.

Alternatively, ADM-CS-EVCC unit has DC contactors feedback inputs. To use them directly instead of this CAN signal, enable them in the /srv/config.cfg file:

[vehicle]
dc_contactors_use_ios = true
Start bit Length (bits) Type Unit Scale Offset Min Max
0 1 Label set 1 0
Label name Value
Open 0
Close 1

Normal_End_of_Charge

Vehicle request a normal charge termination (user request, or soft battery voltage limit reached (eg. bulk charging)).

Only acts on change (so you need to cycle it back to 0).

Alternatively, you can also use the 12V input (R-3F) on ADM-CS-EVCC unit.

Start bit Length (bits) Type Unit Scale Offset Min Max
1 1 Label set 1 0
Label name Value
No_Request 0
Stop_Requested 1

Emergency_Stop

Vehicle request an emergency charge termination Only acts on change (so you need to cycle it back to 0).

Start bit Length (bits) Type Unit Scale Offset Min Max
2 1 Label set 1 0
Label name Value
No_Request 0
Emergency_Stop_Requested 1

Reserved_Flags

Reserved bits for future uses.

Start bit Length (bits) Type Unit Scale Offset Min Max
3 5 Unsigned 1 0

Battery_Voltage

Measurement of battery pack voltage.

Alternatively, this information can be obtained by using a supported CAN sensor. Declare it as such in /srv/config.cfg:

[vehicle]
use_can_sensor = Isabellenhutte IVT-S

In such case, this signal will be ignored. Refer to CAN sensor documentation to know how the sensor should be wired.

Start bit Length (bits) Type Unit Scale Offset Min Max
8 16 Unsigned Volts 0.1 0 0 6553

Inlet_Voltage

Measurement of inlet voltage (ie. before contactors).

Alternatively, this information can be obtained by using a supported CAN sensor. Declare it as such in /srv/config.cfg:

[vehicle]
use_can_sensor = Isabellenhutte IVT-S

In such case, this signal will be ignored. Refer to CAN sensor documentation to know how the sensor should be wired.

Start bit Length (bits) Type Unit Scale Offset Min Max
24 16 Unsigned Volts 0.1 0 0 6553

EV_Energy_Request

* *
Frame ID 0x614
Length [Bytes] 6
Periodicity [ms] 100
Direction IN

Description

ISO 15118-20 specific message. The energy of the EV corresponding to the SOC specified by the owner. The energy request is represented by an energy range including a target energy request.

Energy requests should satisfy the following relationship: Minimum_Energy_Request ≤ Target_Energy_Request ≤ Maximum_Energy_Request

Payload

Signal Length (bits) Type
Target_Energy_Request 16 Unsigned
Maximum_Energy_Request 16 Unsigned
Minimum_Energy_Request 16 Unsigned

Payload description

Target_Energy_Request

The energy of the EV corresponding to the target SOC.

The target energy request can be lower than the current energy level present in the battery represented by the SoC. This represents a discharge request. More details available in the ISO15118-20 documentation.

Start bit Length (bits) Type Unit Scale Offset Min Max
0 16 Unsigned kWh 0.1 0 0 6553

Maximum_Energy_Request

The energy of the EV corresponding the to maximum SOC.

In case this message is not sent we default to the config file entry max_energy_request.

Will be capped by Energy_Capacity.

Start bit Length (bits) Type Unit Scale Offset Min Max
16 16 Unsigned kWh 0.1 0 0 6553

Minimum_Energy_Request

The energy of the EV corresponding to the minimum SOC. In case this message is not sent we default to the config file entry min_energy_request.

Start bit Length (bits) Type Unit Scale Offset Min Max
32 16 Unsigned kWh 0.1 0 0 6553

EV_V2X_Energy_Request

* *
Frame ID 0x615
Length [Bytes] 4
Periodicity [ms] 100
Direction IN

Description

ISO 15118-20 specific message. (Optional) Indicates a preferred operational V2X range for bidirectional cycling. V2X energy requests should satisfy the following relationships: Minimum_Energy_Request ≤ Minimum_V2X_Energy_Request Maximum_V2X_Energy_Request ≤ Maximum_Energy_Request

Payload

Signal Length (bits) Type
Minimum_V2X_Energy_Request 16 Unsigned
Maximum_V2X_Energy_Request 16 Unsigned

Payload description

Minimum_V2X_Energy_Request

The minimum energy level for the bidirectional cycling activity range.

Start bit Length (bits) Type Unit Scale Offset Min Max
0 16 Unsigned kWh 0.1 0 0 6553

Maximum_V2X_Energy_Request

The maximum energy level for the bidirectional cycling activity range.

Start bit Length (bits) Type Unit Scale Offset Min Max
16 16 Unsigned kWh 0.1 0 0 6553

EV_Extra_BPT_Information

* *
Frame ID 0x616
Length [Bytes] 4
Periodicity [ms] 100
Direction IN

Description

ISO 15118-20 specific message. EV extra bidirectional power transfer information.

Payload

Signal Length (bits) Type
Departure_Time 32 Unsigned

Payload description

Departure_Time

Indicate when the EV intends to finish the charging process The offset in seconds from the point in time of sending this message.

Start bit Length (bits) Type Unit Scale Offset Min Max
0 32 Unsigned Seconds 1 0 0 4294967296

ADM_CS_EVCC_MEVC_Outputs

* *
Frame ID 0x617
Length [Bytes] 8
Periodicity [ms]
Direction IN

Description

Controller (ADM-CS-EVCC and ADM-CS-MEVC hardware variant) has various outputs that can be controlled through this message. Only send when a change in the outputs is needed.

Payload

Signal Length (bits) Type
Digital_Output1 1 Single bit
Digital_Output2 1 Single bit
Digital_Output3 1 Single bit
Reserved 37 Unsigned
Led1 8 Unsigned
Led2 8 Unsigned
Led3 8 Unsigned

Payload description

Digital_Output1

Sets the logical state of DIG_OUT1. Needs to be declared as monitored in /srv/config.cfg:

[hardware]
dig_out1 = CAN_Controlled
Start bit Length (bits) Type Unit Scale Offset Min Max
0 1 Single bit 1 0 0 1

Digital_Output2

Reports the logical state of DIG_OUT2. Needs to be declared as monitored in /srv/config.cfg:

[hardware]
dig_out2 = CAN_Controlled
Start bit Length (bits) Type Unit Scale Offset Min Max
1 1 Single bit 1 0 0 1

Digital_Output3

Reports the logical state of DIG_OUT3. Needs to be declared as monitored in /srv/config.cfg:

[hardware]
dig_out3 = CAN_Controlled
Start bit Length (bits) Type Unit Scale Offset Min Max
2 1 Single bit 1 0 0 1

Reserved

Padding bits between digital outputs and leds.

Start bit Length (bits) Type Unit Scale Offset Min Max
3 37 Unsigned 1 0

Led1

Sets the brightness of LED1 (3C1) in a scale from 1 to 100. Greater values than 100 will be treated as max brigthness. Needs to be declared as monitored in /srv/config.cfg:

[hardware]
led1 = CAN_Controlled
Start bit Length (bits) Type Unit Scale Offset Min Max
40 8 Unsigned 1 0 0 255

Led2

Sets the brightness of LED2 (3C2) in a scale from 1 to 100. Greater values than 100 will be treated as max brigthness. Needs to be declared as monitored in /srv/config.cfg:

[hardware]
led2 = CAN_Controlled
Start bit Length (bits) Type Unit Scale Offset Min Max
48 8 Unsigned 1 0 0 255

Led3

Sets the brightness of LED3 (3C3) in a scale from 1 to 100. Greater values than 100 will be treated as max brigthness. Needs to be declared as monitored in /srv/config.cfg:

[hardware]
led3 = CAN_Controlled
Start bit Length (bits) Type Unit Scale Offset Min Max
56 8 Unsigned 1 0 0 255

EV_Status

* *
Frame ID 0x618
Length [Bytes] 8
Periodicity [ms]
Direction IN

Description

Used to report the status of the EV (from BMS to charge controller) Only send when there is a change in the status.

Payload

Signal Length (bits) Type
HV_Preparing_Hold_Off 1 Label set
Charge_Pause_Request 1 Label set
Charge_Resume_Request 1 Label set
ISO15118_Part20_Scheduled_Mode_Control 1 Label set
Reserved_Flags 60 Unsigned

Payload description

HV_Preparing_Hold_Off

Info

Available since version 2.2

Allows the vehicle to delay the transition to powered states (powered states start from the insulation test) until the HV system is ready. Can be set at any time before Communication_Stage.Connected_With_Full_Info state.

Use cases:

  • Make sure the vehicle IMD is disabled before sending cablecheck request.
  • Wait while preparing the HV system for power.

This signal should be set to 0 if the vehicle is ready for power. When the charger is plugged-in and this signal is set to 1, the session will block at Communication_Stage.Connected_With_Full_Info state until this signal is set to 0 (and the inlet is locked).

0=False (Hold off Not Requested), 1=True (Hold off)

Note: limited by wait_hv_ready_timeout_ms config entry. Default is 40 seconds (defined by the standards):

[ccs]
wait_hv_ready_timeout_ms = 40000
Start bit Length (bits) Type Unit Scale Offset Min Max
0 1 Label set 1 0
Label name Value
Hold_Off_Not_Requested 0
Hold_Off 1

Charge_Pause_Request

Info

Available since version 2.4 Supported for CCS with ISO 15118. Not supported for MCS (Megawatt Charging System) protocol.

Allows requesting a pause in energy transfer, in accordance with section CC.3.3 of IEC 61851-23:2023. The pause request is not valid before the charging phase.

Start bit Length (bits) Type Unit Scale Offset Min Max
1 1 Label set 1 0
Label name Value
Not_Requested 0
Requested 1

Charge_Resume_Request

Info

Available since version 2.4 Supported for CCS with ISO 15118. Not supported for MCS (Megawatt Charging System) protocol.

Used to request waking up the charger and resume/restart the charge session, in accordance with section CC.5.2.4 of IEC 61851-23:2023 By performing a B - C - B toggle on the CP line.

Start bit Length (bits) Type Unit Scale Offset Min Max
2 1 Label set 1 0
Label name Value
Not_Requested 0
Requested 1

ISO15118_Part20_Scheduled_Mode_Control

Info

Available since version 2.4

Power transfer in ISO15118-20 Scheduled mode defines that the EVCC shall either provide a EVTargetVoltage or EVTargetCurrent value In a DC_ChargeLoopReq. "The EVCC shall never provide both values in the same message."

This signal is used to select which parameter the user wants to control.

  • If Current_Control is selected, the EVCC will send DC_Status1.Max_Charge_Current as EVTargetCurrent and 0V as EVTargetVoltage.
  • If Voltage_Control is selected, the EVCC will send DC_Status1.Target_Voltage (or the target_voltage from the config file depending on your configuration) as EVTargetVoltage and 0A as EVTargetCurrent.

This signal will be reset to Current_Control when Communication_Stage cycles back to Waiting_For_EVSE. The ISO15118-20 Scheduled-mode control selection can be changed at any time during the charging session.

Start bit Length (bits) Type Unit Scale Offset Min Max
3 1 Label set 1 0
Label name Value
Current_Control 0
Voltage_Control 1

Reserved_Flags

Reserved bits for future uses.

Start bit Length (bits) Type Unit Scale Offset Min Max
4 60 Unsigned 1 0