Overview¶
General operation¶
One way to look at the Advantics controllers is to consider them as mere translators between the communication protocol a charger uses and a protocol BMS of a vehicle uses. It abstracts away the various types of charge communication standards (eg. AC charging, CCS DIN, CCS ISO, etc.) as well as their versions.
But it has to also abstract away the complexity of correctly sequencing BMS, contactors and possibly other devices. Hence, the generic PEV CAN interface is a middle ground between two abstraction layers.
The process of charging a battery is fundamentally driven by what the battery can take at any given moment. In electric vehicle charging it translates to the BMS requesting voltage and current setpoints to power electronics capable of delivering power levels in the order of ten's to hundreds of kilo Watts.
Communication protocols like CCS are here to forward these requests between two independent entities, a vehicle and a charger, addressing all the challenging aspects it can have (interoperability, reliability, etc.). They carry other side tasks such as sharing the voltage, current and power limits of both sides, charge scheduling, authorisation by external payment, Plug'n'Charge, etc.
Attention
It should always be considered that in this process, the vehicle is a master giving its requests to the charger. Actually, CCS took this even further by considering the vehicle is always the one initiating every step of the process, much beyond what the main charging loop requires.
As the role of sequencing is on vehicle side, the generic PEV CAN interface ease the process by only needing some information from VCU and BMS and some controls on DC contactors. It can be made even simpler as our EVCC controller can also directly control contactors and read information from some CAN voltage and current sensors.
Note
In simple AC charging (is. using only PWM control), things are much more simplified, as it is the onboard AC charger doing most of the work.
Some steps in the process are long-lasting. Communication protocols adopted different ways for making these steps cyclic. They generally take the form of loops where the vehicle requests setpoints, and requests are forwarded to power modules. Then readouts from power modules are forwarded to the vehicle, and the vehicle decide to continue the loop or not.
Note
Unlike with other typical CAN communications, cyclicity of requests here is not meant to run as control loops. The vehicle should have its own, safe, control loop for what the battery can take (usually in the BMS directly). The charger should have its own, safe, control loops for the various power modes. Cyclicity of these requests is mostly for slowly moving the setpoints, and for relatively long time outs in case of problem (unexpected disconnection, failure of some modules, power trip on the grid, noise, etc.).
Advantics controllers is hiding all details of the charge process that are not relevant to vehicle control unit (eg. scheduling, authentication, etc.). It will also try its best to capture every possible failure in the communication with the charger in order to properly shut off any active power function running at that time.