Skip to content

BPT (ISO15118-20)

Introduction

The second version of ADVANTICS generic interface for EVCC extends the available CAN bus based API by introducing MCS support and bidirectionality to the controller.

With the support of ISO 15118-20, MCS and bidirectional power transfer became possible through 2 control modes defined by the protocol. In Dynamic control mode, besides the static power transfer parameters, vehicle provides the Energy requests and the range for bidirectional cycling (V2X energy requests).

It is possible to specify the absolute energy requests including the range for bidirectional cycling (V2X energy requests) within the battery capacity limit. Based on these parameters and the state of charge of the battery we will then dynamically calculate relative energy requests and V2X cycling range limits and forward them to the charger.

In addition, the vehicle will be able to specify the time of departure which can be used in dynamic mode.

Note

Generic interface v2 should be used for MCS and BPT applications

Note

Bidirectionality is only available on a special development branch. You need update the containers with the ones provided on this controller's Software Releases page of the download page.

Relevant config entries

Note

When ISO 15118-20 is enabled in the [ccs] section, the ccs-evcc application takes much longer

to load. This performance point will be addressed later.

Changes in the EVCC Generic CAN interface v2:

Name ID Length Direction Cycle time Difference
EV_Information 0x610 3 IN 100 New signal
EV_Energy_Request 0x614 6 IN 100 New message
EV_V2X_Energy_Request 0x615 4 IN 100 New message
EV_Extra_BPT_Information 0x616 4 IN Optional New message

Download CAN DBs:

EV_Information

* *
Frame ID 0x610
Length [Bytes] 3
Periodicity [ms] 100
Direction IN

Description

Information provided by the vehicle.

Payload

Signal Length (bits) Type
State_of_Charge 8 Unsigned
Energy_Capacity 16 Unsigned

Payload description

State_of_Charge

Battery SoC in percent (only used in HLC mode).

Start bit Length (bits) Type Unit Scale Offset Min Max
0 8 Unsigned % 1 0 0 100

Energy_Capacity

The energy capacity of the EV battery. In case this value is 0 we default to the config file entry energy_capacity.

Pleaase note that providing the energy capacity of the battery is mandatory if ISO15118-20 is used.

Start bit Length (bits) Type Unit Scale Offset Min Max
8 16 Unsigned kWh 0.01 0 0 655

EV_Energy_Request

* *
Frame ID 0x614
Length [Bytes] 6
Periodicity [ms] 100
Direction IN

Description

ISO 15118-20 specific message. The energy of the EV corresponding to the SOC specified by the owner. The energy request is represented by an energy range including a target energy request.

Energy requests should satisfy the following relationship:

Minimum_Energy_Request ≤ Target_Energy_Request ≤ Maximum_Energy_Request

Payload

Signal Length (bits) Type
Target_Energy_Request 16 Unsigned
Minimum_Energy_Request 16 Unsigned
Maximum_Energy_Request 16 Unsigned

Payload description

Target_Energy_Request

The energy of the EV corresponding to the target SOC. The target energy request can be lower than the current energy level present in the battery represented by the SoC. This represents a discharge request. More details available in the ISO15118-20 documentation.

Start bit Length (bits) Type Unit Scale Offset Min Max
0 16 Unsigned kWh 0.01 0 0 655

Minimum_Energy_Request

The energy of the EV corresponding to the minimum SOC. In case this message is not sent we default to the config file entry min_energy_request.

Start bit Length (bits) Type Unit Scale Offset Min Max
16 16 Unsigned kWh 0.01 0 0 655

Maximum_Energy_Request

The energy of the EV corresponding the to maximum SOC. In case this message is not sent we default to the config file entry max_energy_request. This value will be capped by Energy_Capacity.

Start bit Length (bits) Type Unit Scale Offset Min Max
16 16 Unsigned kWh 0.01 0 0 655

EV_V2X_Energy_Request

* *
Frame ID 0x615
Length [Bytes] 4
Periodicity [ms] 100
Direction IN

Description

ISO 15118-20 specific message. (Optional) Indicates a preferred operational V2X energy range for bidirectional cycling. V2X energy requests should satisfy the following relationships:

Minimum_Energy_Request ≤ Minimum_V2X_Energy_Request
Maximum_V2X_Energy_Request ≤ Maximum_Energy_Request

Payload

Signal Length (bits) Type
Minimum_V2X_Energy_Request 16 Unsigned
Maximum_V2X_Energy_Request 16 Unsigned

Payload description

Minimum_V2X_Energy_Request

The minimum energy level for the bidirectional cycling activity range.

Start bit Length (bits) Type Unit Scale Offset Min Max
0 16 Unsigned kWh 0.01 0 0 655

Maximum_Energy_Request

The maximum energy level for the bidirectional cycling activity range.

Start bit Length (bits) Type Unit Scale Offset Min Max
16 16 Unsigned kWh 0.01 0 0 655

EV_Extra_BPT_Information

* *
Frame ID 0x616
Length [Bytes] 4
Periodicity [ms] 100
Direction IN

Description

ISO 15118-20 specific message. EV extra bidirectional power transfer information.

Payload

Signal Length (bits) Type
Departure_Time 32 Unsigned

Payload description

Departure_Time

Indicate when the EV intends to finish the charging process. Represents the offset in seconds from the point in time of sending this message.

Start bit Length (bits) Type Unit Scale Offset Min Max
0 32 Unsigned Seconds 1 0 0 4294967296