Skip to content

ORION BMS Integration

This is a guide for integrating Orion BMS with ADVANTICS EVCC for CCS DC charging.

Interface

Integrating the Orion BMS with ADVANTICS EVCC is possible using the CAN Bus PEV Generic Interface and Orion Programmable CANBUS Interface via the ORION BMS Software utility.

To make the communication possible, you only need to configure the BMS to send the messages needed by the PEV CAN Bus Generic interface using the CANBUS settings of the BMS.

2 messages need to be configured. Please refer to Generic PEV CAN interface for detailed information:

  • EV_INFORMATION
  • DC_STATUS1

To edit the CAN messages sent by the Orion BMS, follow these steps:

  1. Launch OrionBMS 2 Utility:
The OrionBMS 2 Utility, with
Figure 60: The OrionBMS 2 Utility, with "Edit CANBUS Messages" highlighted


  1. Press "Edit CANBUS Messages", and configure the signals as shown in the following figure:
Signal configuration in the Orion BMS CANBUS message editor
Figure 61: Signal configuration in the Orion BMS CANBUS message editor

The messages that you should add are:

The CAN messages to add to the Orion BMS configuration
Figure 62: The CAN messages to add to the Orion BMS configuration

Note

For the signals 'Pack CCL' and 'Pack Current' you should change 'field length' to 2 bytes and 'Byte Order' to Little Endian.

Provide Signals not supported by the BMS

Some signals are not supported by the BMS. The solution for that is to provide the missing signals as follows:

Use Isabellenhutte Sensor:

Please refer to CAN sensor to know how the sensor should be wired.

  • Inlet Voltage: According to charging standards, Inlet Voltage should be measured from the vehicle side just before the contactors. It's used mainly during Precharge to close contactors on the correct voltage. Please check CAN sensor to configure the controller to use the Isabellenhutte Sensor.

The following signals should be provided by the sensor even though the BMS can provide them:

  • Present Current: Measurement of current flowing in or out of the battery.
  • Battery Voltage: Measurement of battery pack voltage.

End of Charge:

Use the input "Charge Stop" (3F2) on the ADM-CS-EVCC unit to indicate the end of charge.

Contactors with feedback:

The ADM-CS-EVCC unit has optional DC contactors feedback inputs. Check DC contactors to configure the controller to use contactors with the feedback inputs.